ViveEV Logo

Contact us

Blog
Dive into our blog for in-depth insights, industry trends, and innovations in EV charging. Stay inspired with the latest updates shaping the future of e-mobility.

November 02, 2026

Right Sizing Charging Power: How Driver Behavior Can Lead CPOs to Overbuild

Right-Sizing Charging Power: How Driver Behavior Can Lead CPOs to Overbuild

At charging sites with more than one DC power level, drivers usually pick the stall with the highest kW rating, even when their car can't use that much power.

That creates a planning problem for Charge Point Operators (CPOs). Busy 350 kW stalls look like strong demand for ultra-fast charging. But often, drivers are choosing the biggest number, not getting a much faster charge. If CPOs read that as a signal to build more high power, the next site can end up overbuilt.

Drivers choose the number, not the speed

GIREVE, a European EV roaming platform, studied sites that offer two DC power levels. The faster charger accounted for about 60% of sessions. At highway sites the split was 63/37. Where a 50–60 kW charger sat next to ultra-fast units of 150–460 kW, the faster stalls took 75% of sessions.

The extra power didn't always reach the car. At sites pairing 150 kW and 300 kW chargers, the 300 kW units had twice the rating but delivered only 11% more average power. GIREVE also notes that most sessions are limited to around 100 kW by the vehicle or the grid, whatever the label says.

Part of the reason is simple. Many drivers don't know their car's peak charging rate, so the kW label on the stall is the easiest number to go by. And when prices are the same, there is no reason to pick the slower one.

What this costs CPOs

1. Artificial congestion. Drivers queue for the 350 kW stalls while 150 kW stalls sit empty. The site looks full even when it has capacity to spare.

2. Misused premium hardware. A car that can only take 100 kW can tie up a 350 kW charger for the whole session, while a car that could use the full power waits.

3. Uneven equipment wear. The highest-rated stalls take most of the sessions, so the most expensive equipment wears out first while lower-power units sit underused.

4. Misleading demand signals. High usage on 350 kW stalls can look like proof that the next site needs more ultra-fast hardware. But every extra kilowatt adds cost: larger equipment, bigger grid upgrades and higher demand charges. If average delivered power is low, the better answer may be a more balanced site, not more peak power.

Four levers CPOs can pull

You can't make every driver learn their car's charging curve. But you can design the site so their guess matters less.

  1. Share power across stalls. With a shared power cabinet, power goes to the cars that can use it. A car limited to 100 kW takes 100 kW, and the rest flows to the car beside it. When every stall can reach high power, there's no single "magnet" stall to crowd.

  2. Guide drivers in the app. When the app knows the vehicle, through the driver's account or Plug & Charge, it can recommend the right stall before the driver arrives.

  3. Price the premium. Drivers default to the faster stall when prices match. A slightly higher per-kWh or per-minute rate on top-power stalls gives drivers who don't need the speed a reason to choose another one, and shortens the wait for those who do.

  4. Read your data twice before you build. Before adding high-power units at the next site, compare which stalls drivers chose with how much power those sessions actually delivered (energy divided by session time). If most sessions on the 350 kW stall averaged under 100 kW, the next site may need more stalls, not more power.

How viveEV helps

Tron connects one 600 kW power cabinet to up to four dispensers and uses AI-powered dynamic power sharing to distribute power based on real-time demand. Each car draws what it can accept, and the rest goes to the next dispenser, so no single stall becomes the magnet.

Nova is an all-in-one 180 kW DC fast charger with NACS and CCS1 connectors. With two cars plugged in, it delivers up to 90 kW to each, close to the power most sessions actually use. That makes it a cost-effective fit for the stalls that carry everyday demand.

viveEV's in-house software closes the loop. Session records show charging time and energy for every stall, so operators can compare where drivers plugged in with the power they actually received. Ember, the software agent on each charger, monitors charger health in real time and sends instant alerts, while Nexus brings monitoring and maintenance for every site into one view.

Drivers will usually pick the biggest number. That's normal. The risk for CPOs is treating that habit as real demand for high power.

The best charging sites aren't always the ones with the most power. They are the ones where drivers are guided clearly, power goes where it's needed, and every charger earns its place in the business case.